TY - GEN
T1 - Effect of leaflet geometry on mechanical performance of stentless pericardial aortic valves
T2 - World Congress on Medical Physics and Biomedical Engineering: Image Processing, Biosignal Processing, Modelling and Simulation, Biomechanics
AU - Xiong, F. L.
AU - Goetz, W. A.
AU - Chua, Y. L.
AU - Zhang, P.
AU - Pfeifer, S.
AU - Wintermantel, E.
AU - Yeo, Joon Hock
PY - 2009
Y1 - 2009
N2 - Recent developments in aortic valve replacement include the truly stentless pericardial bioprostheses with Single Point Attached Commissures (SPAC). The leaflet geometry available for these valves can be a simple tubular or a complex three-dimensional molded structure resembling the natural valve. We compared mechanical performance of these two valve designs via dynamic simulation. Surface models representing a tubular valve and a molded valve incorporating the aortic root of 25 mm in diameter were created. An elastic modulus of 8 MPa and a density of 1,100 kg/m3 were assigned to the pericardial leaflet tissue. Time-varying physiological pressure loadings over a full cardiac cycle were applied on the upper and lower aortic root wall, and aorto-ventricular pressure gradient applied on the valve leaflets. The maximum effective valve orifice area during systole is 400.6 and 633.5 mm2 for the tubular and the molded valves, respectively. When fully closed, the free edges in the molded valve form S-shaped lines characterized by twisting at the valve center, a phenomenon not apparent in the tubular valve. Consequently, the coaptation height in the former is nearly four times greater than in the latter, being 4.5 and 1.2 mm, respectively. Computed compressive stress indicates that high magnitude in the tubular valve prevails at the commissure, along the inter-leaflet margin and the leaflet basal attachment line, while in the molded valve it occurs at the center of the free edge and on the leaflet belly. The highest stress magnitude in the tubular is 3.83 MPa versus 1.80 MPa in the molded. The molded leaflet geometry resembling the natural valve performs better than the simple tubular geometry for the SPAC valves, by producing greater effective orifice area, better coaptation properties, and lower magnitude in compressive stress, which should translate into enhanced valve efficacy and durability.
AB - Recent developments in aortic valve replacement include the truly stentless pericardial bioprostheses with Single Point Attached Commissures (SPAC). The leaflet geometry available for these valves can be a simple tubular or a complex three-dimensional molded structure resembling the natural valve. We compared mechanical performance of these two valve designs via dynamic simulation. Surface models representing a tubular valve and a molded valve incorporating the aortic root of 25 mm in diameter were created. An elastic modulus of 8 MPa and a density of 1,100 kg/m3 were assigned to the pericardial leaflet tissue. Time-varying physiological pressure loadings over a full cardiac cycle were applied on the upper and lower aortic root wall, and aorto-ventricular pressure gradient applied on the valve leaflets. The maximum effective valve orifice area during systole is 400.6 and 633.5 mm2 for the tubular and the molded valves, respectively. When fully closed, the free edges in the molded valve form S-shaped lines characterized by twisting at the valve center, a phenomenon not apparent in the tubular valve. Consequently, the coaptation height in the former is nearly four times greater than in the latter, being 4.5 and 1.2 mm, respectively. Computed compressive stress indicates that high magnitude in the tubular valve prevails at the commissure, along the inter-leaflet margin and the leaflet basal attachment line, while in the molded valve it occurs at the center of the free edge and on the leaflet belly. The highest stress magnitude in the tubular is 3.83 MPa versus 1.80 MPa in the molded. The molded leaflet geometry resembling the natural valve performs better than the simple tubular geometry for the SPAC valves, by producing greater effective orifice area, better coaptation properties, and lower magnitude in compressive stress, which should translate into enhanced valve efficacy and durability.
KW - Dynamic simulation
KW - Leaflet geometry
KW - Pericardial aortic valves
KW - Single point attached commissures
KW - Stentless
UR - http://www.scopus.com/inward/record.url?scp=77950172124&partnerID=8YFLogxK
U2 - 10.1007/978-3-642-03882-2_44
DO - 10.1007/978-3-642-03882-2_44
M3 - Conference contribution
AN - SCOPUS:77950172124
SN - 9783642038815
T3 - IFMBE Proceedings
SP - 1657
EP - 1660
BT - World Congress on Medical Physics and Biomedical Engineering
PB - Springer Verlag
Y2 - 7 September 2009 through 12 September 2009
ER -