TY - JOUR
T1 - Dried blood spot collection, sample quality, and fieldwork conditions
T2 - Structural validations for conversion into standard values
AU - Börsch-Supan, Axel
AU - Weiss, Luzia M.
AU - Börsch-Supan, Martina
AU - Potter, Alan J.
AU - Cofferen, Jake
AU - Kerschner, Elizabeth
N1 - Publisher Copyright:
© 2020 The Authors. American Journal of Human Biology published by Wiley Periodicals LLC.
PY - 2021/7/1
Y1 - 2021/7/1
N2 - Objectives: SHARE, a pan-European panel study in 27 European countries and Israel, has collected dried blood spot (DBS) samples from approximately 27 000 respondents in 13 countries. We aim to obtain factors to convert analyte values between DBS and venous blood samples (VBS) taking account of adverse fieldwork conditions such as small spot size, high temperature and humidity, short drying time and long shipment times. Methods: We obtained VBS and DBS from a set of 20 donors in a laboratory setting, and treated the DBS in a systematic and controlled fashion simulating SHARE fieldwork conditions. We used the 3420 outcomes to estimate from DBS analyte values the values that we would have obtained had it been feasible to collect and analyze the donors' venous blood samples. Results: The influence of field conditions and sample quality on DBS analyte values is significant and differs among assays. Varying spot size is the main challenge and affects all markers except HbA1c. Smaller spots lead to overly high measured levels. A missing desiccant is detrimental for all markers except CRP and tHb. The temperature to which the samples are exposed plays a significant role for HDL and CysC, while too brief a drying time affects CRP and CysC. Lab-based adjustment formulae only accounting for the differences between re-liquefied DBS and venous blood do not address these fieldwork conditions. Conclusions: By simulating adverse fieldwork conditions in the lab, we were able to validate DBS collected under such conditions and established conversion formulae with high prediction accuracy.
AB - Objectives: SHARE, a pan-European panel study in 27 European countries and Israel, has collected dried blood spot (DBS) samples from approximately 27 000 respondents in 13 countries. We aim to obtain factors to convert analyte values between DBS and venous blood samples (VBS) taking account of adverse fieldwork conditions such as small spot size, high temperature and humidity, short drying time and long shipment times. Methods: We obtained VBS and DBS from a set of 20 donors in a laboratory setting, and treated the DBS in a systematic and controlled fashion simulating SHARE fieldwork conditions. We used the 3420 outcomes to estimate from DBS analyte values the values that we would have obtained had it been feasible to collect and analyze the donors' venous blood samples. Results: The influence of field conditions and sample quality on DBS analyte values is significant and differs among assays. Varying spot size is the main challenge and affects all markers except HbA1c. Smaller spots lead to overly high measured levels. A missing desiccant is detrimental for all markers except CRP and tHb. The temperature to which the samples are exposed plays a significant role for HDL and CysC, while too brief a drying time affects CRP and CysC. Lab-based adjustment formulae only accounting for the differences between re-liquefied DBS and venous blood do not address these fieldwork conditions. Conclusions: By simulating adverse fieldwork conditions in the lab, we were able to validate DBS collected under such conditions and established conversion formulae with high prediction accuracy.
UR - http://www.scopus.com/inward/record.url?scp=85092543215&partnerID=8YFLogxK
U2 - 10.1002/ajhb.23517
DO - 10.1002/ajhb.23517
M3 - Article
C2 - 33063418
AN - SCOPUS:85092543215
SN - 1042-0533
VL - 33
JO - American Journal of Human Biology
JF - American Journal of Human Biology
IS - 4
M1 - e23517
ER -