Abstract
A Hybrid Heat Transfer Coefficient module has been developed based on two Surface Renewal Theory models using CFD simulations. The validation of the model has been done on a meso-scale computational grid for CFD simulations and on a macro-scale computational grid for System Code analysis. The CFD simulation was performed for a stratified co-current two phase flow between saturated steam and sub-cooled water while the System Code analysis was performed for a Condensation Induced Water Hammer experiment.
| Originalsprache | Englisch |
|---|---|
| Seiten (von - bis) | 25-30 |
| Seitenumfang | 6 |
| Fachzeitschrift | Kerntechnik |
| Jahrgang | 78 |
| Ausgabenummer | 1 |
| DOIs | |
| Publikationsstatus | Veröffentlicht - März 2013 |
Fingerprint
Untersuchen Sie die Forschungsthemen von „Development of a 1 D hybrid HTC model using CFD simulations for the analysis of direct contact condensation as the driving force for water hammers“. Zusammen bilden sie einen einzigartigen Fingerprint.Dieses zitieren