Complicated Sternal Dehiscence: Reconstruction With Plates, Cables, and Cannulated Screws

Bernhard Voss, Robert Bauernschmitt, Gernot Brockmann, Markus Krane, Albrecht Will, Rüdiger Lange

Publikation: Beitrag in FachzeitschriftArtikelBegutachtung

11 Zitate (Scopus)

Abstract

Sternal dehiscence after median sternotomy can be a challenging problem in case of multiple fractures or infection. For sternal refixation, the principles of rigid plate and screw osteosynthesis gained from orthopedic surgery have been recommended by several authors. We present a new system for sternal reconstruction consisting of reconstruction plates, steel cables, and cannulated screws.

OriginalspracheEnglisch
Seiten (von - bis)1304-1306
Seitenumfang3
FachzeitschriftAnnals of Thoracic Surgery
Jahrgang87
Ausgabenummer4
DOIs
PublikationsstatusVeröffentlicht - Apr. 2009

Fingerprint

Untersuchen Sie die Forschungsthemen von „Complicated Sternal Dehiscence: Reconstruction With Plates, Cables, and Cannulated Screws“. Zusammen bilden sie einen einzigartigen Fingerprint.

Dieses zitieren