Coherence and wavefront characterization of Si-111 monochromators using double-grating interferometry

Ana Diaz, Cristian Mocuta, Julian Stangl, Mario Keplinger, Timm Weitkamp, Franz Pfeiffer, Christian David, Till H. Metzger, Günther Bauer

Publikation: Beitrag in FachzeitschriftArtikelBegutachtung

43 Zitate (Scopus)

Abstract

A study of the coherence and wavefront properties of a pseudo-channel-cut monochromator in comparison with a double-crystal monochromator is presented. Using a double-grating interferometer designed for the hard X-ray regime, the complex coherence factor was measured and the wavefront distortions at the sample position were analyzed. A transverse coherence length was found in the vertical direction that was a factor of two larger for the channel-cut monochromator owing to its higher mechanical stability. The wavefront distortions after different optical elements in the beam, such as monochromators and mirrors, were also quantified. This work is particularly relevant for coherent diffraction imaging experiments with synchrotron sources.

OriginalspracheEnglisch
Seiten (von - bis)299-307
Seitenumfang9
FachzeitschriftJournal of Synchrotron Radiation
Jahrgang17
Ausgabenummer3
DOIs
PublikationsstatusVeröffentlicht - 2010

Fingerprint

Untersuchen Sie die Forschungsthemen von „Coherence and wavefront characterization of Si-111 monochromators using double-grating interferometry“. Zusammen bilden sie einen einzigartigen Fingerprint.

Dieses zitieren