Active pump-seed-pulse synchronization for OPCPA with sub-2-fs residual timing jitter: erratum

Stephan Prinz, Matthias Häfner, Marcel Schultze, Catherine Y. Teisset, Robert Bessing, Knut Michel, Reinhard Kienberger, Thomas Metzger

Publikation: Beitrag in FachzeitschriftArtikelBegutachtung

1 Zitat (Scopus)

Abstract

In the original manuscript, a residual RMS timing jitter below 2 fs between pump and seed pulses in the stabilized case was claimed. Following a reevaluation of the data, this was underestimated. Due to a rounding error in the calibration routine, a miscalculated calibration factor was extracted. By using a higher precision, the updated residual timing jitter amounts to 2.76 fs, or sub-3 fs. In this erratum, the calibration routine is briefly reviewed and Fig. 4, which presents the timing jitter in the stabilized and unstabilized case, is updated. All other results remain unaffected.

OriginalspracheEnglisch
Seiten (von - bis)5512-5513
Seitenumfang2
FachzeitschriftOptics Express
Jahrgang26
Ausgabenummer5
DOIs
PublikationsstatusVeröffentlicht - 5 März 2018